MULTI-BATTERY ISOLATOR APPLICATION & INSTALLATION INSTRUCTIONS

  1. After completing step #4 of standard instructions, remove the two screws attaching the regulator. With great care, remove the regulator. Use a downward, rolling motion to prevent breaking off the brushes.
  2. Bend the connector prong of the alternator, as illustrated, so that it will not longer mate with the internal connection strap of the regulator. (The regulator connector may need to be bent also to insure no contact.)
  3. Solder an appropriate length of #14 wire to the regulator connector prong, as was bent in step #2 (see illustration).
  4. Replace regulator, Note: suggest a flat blade to hold the brushes in the holder until the regulator is in place. Replace mounting screws (route wire so it will not be pinched or in the way).
  5. Connect the other end off the wire that was soldered on the regulator to the R terminal on the isolator. Colored terminal indicates R post.
  6. Disconnect the wire(s) going to the D+ terminal of the alternator.
  7. Reconnect these same wire(s) to the R terminal of the isolator with the wire connected in step #5 above.
  8. Now proceed to step #5 of the GENERAL ISOLATOR INSTALLATION INSTRUCTIONS